+86 189 8978 2810

+86 189 8978 2810

Side Mount Stainless Steel Float Level Switch(single ball)

Case Quantity
Minimum : 0 Maximum : Unlimited

304 stainless steel side mount float switch

Compact design with easy installation

Corrosion-resistant and high-temperature resistant

Laser seamless welding for durability

Strong sealing with epoxy resin and rubber gasket

Elbow pipe design, customizable structure

Download Catalog
Download
share item:
DETAILS DOWNLOADS FAQS

Application

  • Water tanks and storage containers
  • Water heaters and solar water systems
  • Drinking machines and water purifiers
  • Coffee machines and humidifiers
  • Air conditioners and small refrigeration systems
  • Industrial liquid level control equipment
  • Agricultural irrigation systems
  • Household appliances with liquid level monitoring
  • Automotive and mechanical equipment

Description

The 304 stainless steel side mount float level switch(single ball) is a compact and reliable liquid level sensor designed for precise water level control in tanks and containers. Made of high-quality 304 stainless steel, it offers excellent corrosion resistance, high-temperature resistance, and long service life. The elbow pipe design allows flexible side installation, while laser seamless welding ensures a strong and durable structure. With epoxy resin sealing and thickened rubber gaskets, it provides excellent waterproof performance and protects the internal reed switch from moisture and foreign objects.

Features

  • 304 stainless steel construction for durability and corrosion resistance
  • Side mount elbow pipe design for flexible installation
  • Compact and delicate structure, suitable for limited spaces
  • Laser seamless welding for stronger and more beautiful appearance
  • Thickened rubber gasket with strong waterproof performance
  • Anti-oxidation sealing design for humid environments
  • High-quality stainless steel retaining clip for stable operation
  • Supports customization for pipe shape and installation requirements
  • Stable reed switch performance with long service life

Technical Details

Product Type:

Float Level Switch

Product Model:

ESC7810 ESC12210 ESC20010 ESC30010 ESC40010 ESC50010 ESC60010 ESC70010 ESC80010 ESC90010 ESC100010 ESC110010 ESC120010

Material:

304 Stainless Steel

Size:

See attached drawing

Type:

Side Mount Stainless Steel Float Level Switch(single ball)

Temperature Range:

-30°C to +120°C

Max Contact Rating:

10VA (1A1) / 50VA (2A1)

Max Switching Voltage:

100V AC/DC (1A1) / 220V AC/DC (2A1)

Max Switching Current:

0.5A (1A1) / 1.5A (2A1)

Max Breakdown Voltage:

110V AC/DC (1A1) / 300V AC/DC (2A1)

Max Load Current:

1.0A (1A1) / 3.0A (2A1)

Max Contact Resistance:

100mΩ (1A1 / 2A1)

Accessories

We reserve the right to make technical alterations without prior notice.

ESC Side Mount Stainless Steel Float Level Switch dimensions(single ball)

What is a single-ball side mount stainless steel float level switch used for?

This float switch is mainly used for liquid level detection and automatic control in tanks, water reservoirs, chemical containers, oil tanks, sewage treatment systems, and industrial automation equipment. It helps control pumps, alarms, solenoid valves, and level monitoring systems. ELECALL side-mounted stainless steel float switches are commonly applied in water treatment, petrochemical, metallurgy, and industrial tank systems.

What material is the float switch made of?

The standard model uses SU304 stainless steel, including both the float ball and the float body, which provides: Excellent corrosion resistance High temperature resistance Strong mechanical strength Long service life Suitable for water and many industrial liquids For stronger corrosion resistance, some applications may also require 316 stainless steel customization. The product page also mentions available options in both 304 and 316 stainless steel.

Is this switch normally open (NO) or normally closed (NC)?

It supports both. The float ball can be manually reversed by 180° rotation, allowing users to switch between: Lower-open state Upper-open state Factory default is usually the lower-open setting. This gives buyers more installation flexibility depending on control logic requirements.

Can the float switch directly control pumps or solenoid valves?

No. Because the internal reed switch carries only a small current, it should not directly control high-power loads such as: Water pumps Solenoid valves AC contactors Large alarms Recommended solution: For alarms or solenoid valves → use a small relay (such as HH54P / HH52P) For water pumps → use relay + AC contactor Direct connection may burn the reed contacts.

What is the control stroke of the single-ball float switch?

The control stroke is usually 10mm, which means it is highly sensitive and suitable for precise liquid level detection. If a larger liquid level difference is required, buyers can choose: Two single-ball switches installed at different heights One double-ball float switch This improves level control range.

Can the rod length and thread size be customized?

Yes. ELECALL supports: Rod length customization Thread size customization Float quantity customization Special mounting requirements OEM / ODM production This is especially useful for distributors, equipment manufacturers, and project buyers. ELECALL also highlights OEM/ODM support and low MOQ sourcing.

Is it suitable for dirty water or liquids with debris?

Not recommended. Because the reed switch stroke is small and highly sensitive, it performs best in: Clean water Light industrial liquids Low-viscosity media For liquids containing: Floating debris Heavy sediment Thick sludge buyers should consider more heavy-duty float switches or cable float switches.

Can the float position be adjusted freely?

No. The float ball position is fixed by circlips, and the internal reed switch position cannot be moved. Simply moving the circlips will not change the switching point effectively. If special switching positions are required, buyers should request customized dimensions from the manufacturer.

What should buyers confirm before purchasing?

Before placing an order, buyers should confirm: Liquid type (water / oil / chemical / wastewater) Working temperature Working pressure Installation direction Mounting thread size Rod length Required cable length NO or NC logic Voltage/current requirements Quantity and customization needs Clear specifications help avoid installation problems later.

Does ELECALL support bulk orders and distributor cooperation?

Yes. ELECALL is a professional industrial measurement and control manufacturer founded in 2008, providing: CE / ROHS certified products OEM / ODM customization Factory-direct pricing Low MOQ Export support Distributor cooperation This makes them suitable for wholesalers, importers, and industrial system integrators.

How can buyers choose between single-ball and double-ball models?

Choose single-ball if: Space is limited Precise point-level detection is needed Compact installation is required Choose double-ball if: Larger level differential is needed Pump start/stop control requires wider range More stable switching is preferred The application scenario determines the better choice.

Similar Products

Differential Pressure Switch

The EDPS series differential pressure switch is a special type of control switch. It is a kind of switch that controls closing or opening based on the pressure difference between mutual components and relies on electrical signals for information transmission.

Small Stainless Steel Float Switch

Floats are available in 1–4 pieces (optional,or more), and the rod length can be customized.

Notes:Float switches cannot directly control solenoid valves, high-power relays, AC contactors, etc. A small relay HH45P is required for transition.

Meetyour choices

Small and exquisite

stable performance

Simple installation

REED

EM2000H Digital Micro Differential Pressure Gauge Controller

High-precision digital micro differential pressure controller

LCD real-time display with digital filtering technology

Standard 4–20mA output with optional RS485 communication

24V DC powered industrial pressure monitoring device

Multiple pressure unit switching supported

Suitable for HVAC, cleanroom, and negative pressure systems

Bimetallic Thermo Gauge

High-Sensitivity Temperature Sensor

-40~600℃ (Customizable Range)

Target Flow Switch

Easy to install with high safety and reliability. It adopts a plastic base paired with brass threads, available in multiple piping sizes such as 1/2 inch, […]

YTN-100BF Full Stainless Steel Pressure Gauge

It is suitable for measuring the pressure of liquids, vapors, gases and other media that are non-explosive, non-crystallizing, non-coagulating and non-corrosive to copper and copper-aluminum alloys.

EM2000S Digital Differential Pressure Gauge

High-precision digital differential pressure measurement with clear real-time LCD display

Multiple pressure unit switching

Suitable for HVAC and cleanroom applications

Fast response with strong anti-interference capability

Tubular thermal resistor

Equipped with a stainless steel protection tube, it features high accuracy and excellent stability. It is used to convert temperature signals into usable output signals and is suitable for industrial temperature measurement scenarios.

ECY-80X Digital Pressure Gauge

Its functions can almost completely replace those of mechanical contact pressure gauges, with customizable connectors and measurement ranges

ELE-801 Series Pressure Transmitter

It adopts a 304 stainless steel housing and is equipped with a high-quality wafer core. Multiple types of connectors are available. After precise calibration and aging testing, it features accurate measurement, high stability and strong durability

Get a Quote

    Cart
    Apply coupon
    Subtotal:
    $
    Total:
    $